OILFIELD EQUIPMENT · INTERNATIONAL SUPPLY
MPD Electrically Controlled Choke ManifoldOEIL / EQUIPMENT REFERENCE
Well Control

MPD Electrically Controlled Choke Manifold

YFMPD105-12-2

YFMPD105-12-2 MPD choke manifold with electric servo valve control, synchronized local/remote stations and pressure monitoring. View reference specifications.

Share your application and required configuration for a project-specific quotation.

WHAT IT DOES

Product overview

The YFMPD105-12-2 MPD electrically controlled choke manifold combines electric choke-valve actuation with pressure monitoring and synchronized local and remote control stations. The reference control system includes local and remote electrical cabinets, an industrial computer, servo drives and pressure transmitters for valve-position control and live equipment status.

The catalog describes local manual, remote manual and computer-automatic control modes. Physical controls take priority over software, with emergency stop assigned the highest priority. Two servo actuators provide closed-loop position feedback, while two pressure transmitters monitor standpipe and casing pressure.

The specifications below describe the catalog reference control configuration. Confirm the complete manifold pressure rating, bore, valve arrangement, connections, hazardous-area requirements and documentation against the offered equipment before ordering. An IoT gateway and cloud monitoring are optional.

Local manual, remote manual and computer-automatic control
Two electric servo actuators with closed-loop position feedback
Synchronized local and remote valve-position, pressure and fault displays
Standpipe and casing pressure monitoring
Physical control priority and highest-priority emergency stop
Optional cloud data, historical curves and fault notifications
THE TECHNICAL DETAILS

Reference specifications

ParameterSpecification
Reference modelYFMPD105-12-2
Control objectElectric choke valve
Servo actuator quantity2
Servo actuator rated power1 kW
Servo actuator rated thrust≥ 50 kN
Effective actuator stroke62 mm
Full-stroke opening / closing time≤ 15 s
Pressure transmitter quantity2; standpipe and casing pressure monitoring
Pressure transmitter measurement range0–5,000 psi
Pressure transmitter catalog rating10,000 psi; component rating, not the complete manifold working pressure
Pressure measurement accuracyClass 0.25
Catalog electrical protection designationEx d IIB T4; confirm the offered configuration and supporting documents
Power supplyAC 380 V, three-phase, five-wire; ±10% voltage fluctuation
Servo unit operating temperature−40 °C to +80 °C; servo unit specification
Control modesLocal manual / remote manual / computer automatic
Communication interfacesProfibus / Profinet bus; Ethernet
Analog signal output4–20 mA
Optional functions4G/5G gateway, cloud monitoring and alarm notifications

Reference configuration from the OEIL catalog. Final specifications, document scope and suitability are confirmed in the quotation.

View the source catalog, PDF pages 74–75
HELP US SPECIFY YOUR EQUIPMENT

What to include in your enquiry

  • MPD application, process schematic and required control scope
  • Complete manifold working pressure, nominal bore, flow medium and design temperature
  • Valve arrangement, inlet/outlet connections and actuator requirements
  • Pressure transmitter ranges, locations and signal interfaces
  • Electrical supply, local/remote station layout and communication protocol
  • Hazardous-area classification and required certification/document scope
  • Required IoT gateway, cloud monitoring and alarm functions
COMMON QUESTIONS

Before you enquire

What control modes does the reference configuration provide?+

The catalog lists local manual, remote mirrored manual and computer-automatic control. Local and remote stations synchronize valve position, pressure readings and fault status. Confirm the required control functions and interfaces in the quotation.

Do the transmitter pressure figures define the complete manifold pressure rating?+

No. The 0–5,000 psi measurement range and 10,000 psi catalog rating refer to the pressure transmitters. The complete manifold working pressure, bore, valve arrangement and connection ratings require separate confirmation for the offered equipment.

Is cloud monitoring included as standard?+

The IoT gateway and 4G/5G cloud platform are optional. Specify whether remote data, historical curves and alarm notifications are required so the communication and supply scope can be confirmed.

What hazardous-area documents should be requested?+

The catalog specification lists an Ex d IIB T4 electrical designation. Provide the installation-area classification and the required local or project certification scheme. The offered equipment and supporting documents must be checked for the intended project; the catalog designation alone is not an ATEX or IECEx certificate.

LET’S DEFINE YOUR REQUIREMENT

Your next project
starts with a conversation.

Talk to OEIL
OEIL / TECHNICAL RESOURCES

Download catalog

Please leave your contact for us to provide a better service

We’ll use these details to respond to your catalog request. Privacy policy