Three-Circuit Automatic Inside BOP Test System
YFSY150-3
An automatic test package with three circuits for inside BOP testing and hydraulic control of the test arrangement.
View equipment
OEIL / EQUIPMENT REFERENCEYFD-SY four-cylinder series
High / Low Pressure Four-Cylinder Test Pumps for workshop hydrostatic testing, with the catalog model range shown below.
Share your application and required configuration for a project-specific quotation.
High / Low Pressure Four-Cylinder Test Pumps for workshop hydrostatic testing, with the catalog model range shown below.
Select the pump by required pressure, delivery volume, available power and test-medium compatibility. The table gives model-specific reference values for quotation review.
| Model | High-stage pressure (MPa) | Low-stage flow (L/h) | High-stage flow (L/h) |
|---|---|---|---|
| YFD-SY380/5 | 5 | 750 | 380 |
| YFD-SY240/6.3 | 6.3 | 580 | 240 |
| YFD-SY190/10 | 10 | 580 | 190 |
| YFD-SY140/16 | 16 | 500 | 140 |
| YFD-SY90/25 | 25 | 460 | 90 |
| YFD-SY50/40 | 40 | 400 | 50 |
| YFD-SY32/63 | 63 | 400 | 32 |
| YFD-SY25/80 | 80 | 400 | 25 |
| YFD-SY20/100 | 100 | 400 | 20 |
The two flow columns refer to separate pressure stages.
| Parameter | Specification |
|---|---|
| Reference model / series | YFD-SY four-cylinder series |
| High-stage pressure range | 5–100 MPa across listed models |
| Pump arrangement | Four cylinders; high / low pressure stages |
Reference configuration from the OEIL catalog. Final specifications, document scope and suitability are confirmed in the quotation.
View the source catalog, PDF pages 42–43Provide the reference model, quantity, working medium, required pressure and flow, connection standard and delivery destination.
Yes. Final dimensions, materials, connections and document scope are confirmed against the selected configuration in the quotation.