Drilling Rig Anti-Lifting Safety Device
YFFT-II
The YFFT-II combines pneumatic and hydraulic control for a drilling rig anti-lifting safety device.
View equipment
OEIL / EQUIPMENT REFERENCEWCP2018-PM-HM-2E-3K-4E
A dual-valve wellhead control panel combining pneumatic and manual hydraulic pumping with emergency shutdown functions.
Share your application and required configuration for a project-specific quotation.
This wellhead control panel supplies hydraulic pressure to surface and subsurface safety-valve actuators. The catalog configuration includes a pneumatic hydraulic pump, manual pump, reservoir and accumulator within a stainless-steel cabinet.
Control functions include local and remote emergency shutdown and pressure-related shutdown logic. The actual sequence, actuator volumes, set points and interfaces must be defined for the wellhead installation. A project quotation should state the complete control and documentation scope.
| Parameter | Specification |
|---|---|
| Reference model | WCP2018-PM-HM-2E-3K-4E |
| Main working pressure | 3,000 psi (21 MPa) |
| Maximum system pressure rating | 4,000 psi |
| Reference reservoir | 30 L |
| Cabinet | 304 stainless steel; IP55 |
| Reference ambient range | −20°C to +65°C |
Reference configuration from the OEIL catalog. Final specifications, document scope and suitability are confirmed in the quotation.
View the source catalog, PDF pages 78–79It describes the reference panel arrangement. Valve actuators, shutdown logic and connections must be matched to your installation.
No. Actuator volumes, shutdown requirements, available utilities and the operating environment are also required.
Include actuator data sheets, a control schematic or cause-and-effect description, utility information and the required document list.